HA Convention 2019
簡體
繁體
EN
Login
HA Convention 2019
Toggle navigation
Home
Convention Main Focus
Committees
Speakers
Programme Schedule
Programme at a Glance
Invitation of Abstract
Submitted abstracts
Professional Accreditation
Convention Registration (Closed)
Sponsorship and Exhibition
Sponsors
Convention Information
Information about Hong Kong
Accommodation
Photo Gallery
Attendance Certificate
Contact Us
Feedback
Login
Prospective and Randomized Comparison of Manual Syringe Aspiration Versus Self-Syringe Aspiration for Deflating Foley Catheter Balloon
This abstract has open access
Abstract Description
Abstract ID :
HAC886
Submission Type
HA Staff
Presentation Upload :
View Attachment
If the file does not load,
click here
to open/download the file.
Close
Authors (including presenting author) :
Sy YW (1), Lau KY (1), So WL (1), Lui KL (1), Kung WC (1), Chan NH (1), Li CM (1), Tang CN (1)
Affiliation :
(1) Department of Surgery, Pamela Youde Nethersole Eastern Hospital
Introduction :
Urethral catheter removal can sometimes be an unpleasant and painful experience. Different deflation methods may cause the collapse of balloon membrane inflation lumen and incomplete balloon deflation. The deformed catheter balloon can be felt passing down the urethra, with some patients experiencing urethral discomfort. The two most common ways to deflate Foley catheter balloon are manual syringe aspiration and self-syringe aspiration. However, there has been limited research or investigation to support the use of which method.
Objectives :
To investigate the changes in Foley catheter balloon following deflation and removal with manual aspiration and self-syringe aspiration.
Methodology :
Patients with Fr.14 silicone coated latex Foley catheter in-situ for more than one week and planned for TWOC in Surgical day ward were recruited in the trial. Patients were excluded if they met the following criteria: 1) Cognitive and psychiatric deficits; 2) Patients have any urethral stricture; 3) Patients have undergone radical prostatectomy or 4) With signs and symptoms of urinary tract infection. After initial assessment, the patients were divided randomly into two groups: 1) Control group (Manual syringe aspiration) - Gently aspirate to withdraw the fluid from the balloon & 2) Intervention group (Self-syringe aspiration) - Do not use suction on the syringe but allow the solution to come out spontaneously. Foley catheters were removed by Urology Nurse and the following outcomes were collected after removal of Foley catheter: • Failure rate of balloon deflation • Numeric Rating Scale (NRS) for pain assessment • Time of using self-syringe aspiration or manual aspiration for balloon deflation. • Any further water (in ml) to be aspirated for intervention group after spontaneous aspiration
Result & Outcome :
Seventy-two patients (36 in intervention group: 36 in control group) were recruited to the study from 1st October 2018 to 31st December 2018. All of the Foley balloon were successfully deflated during removal. In regard to the NRS for pain assessment, the mean score of control arm was 1.06/10, the intervention group was 1.72/10 (P>0.05). The mean of time of using for balloon deflation in control arm was 8.21 seconds; compared with intervention arm was 12.13 seconds (P< 0.05). There was no further water to be aspirated at the end in intervention group. In conclusion, there is no significant different in outcomes by using two methods to deflate the Foley balloon. However, it is more time saving to deflate the Foley balloon by manual aspiration.
Author
YS
Y W SY
Abstracts With Same Type
Abstract ID
Abstract Title
Abstract Topic
Submission Type
Primary Author
HAC78
HONG KONG SPECIAL ADMINISTRATIVE REGION GOVERNMENT’S PROPOSED VOLUNTARY HEALTH INSURANCE SCHEME (VHIS): FACTORS INFLUENCING MAJOR CORPORATIONS AND THEIR EMPLOYEES IN TAKING UP THE SCHEME
Healthcare Advances, Research and Innovations
HA Staff
Jamila Ismail
HAC720
Target -oriented Artificial Nutrition Support in Intensive Care Unit (ICU)
Clinical Safety and Quality Service I
HA Staff
Maria SINN Dr
HAC100
“95210 for Health”- an Easy-to-remember Formula to Combat Childhood Obesity
HA Staff
Hak Yung Ng
HAC456
" At Home With Love" a model of Medical Social Collaboration in Public Estates at Shamshuipo
Enhancing Partnership with Patients and Community
HA Staff
Donna TSE
HAC603
"A Well-nourished Hospital" The Donabedian Model approach to enhance patients' nutrition wellness in their hospital journeys
Clinical Safety and Quality Service III
HA Staff
Terry Ho Yan TING Dr
HAC1219
10 Years Experiences on Carer Empowerment to Improve the Performance and Service Outcomes in Residential Care Homes for the Elderly
Enhancing Partnership with Patients and Community
HA Staff
W S KWAN
HAC918
2-year review of Prediabetes Program in Primary Care Setting – Kowloon West Cluster
HA Staff
Christine NG
HAC1262
30-Day Mortality in Palliative Radiotherapy
Enhancing Partnership with Patients and Community
HA Staff
S F LEE Dr
HAC997
5S-Strategy to Reduce Fall Rate for High-Risk Groups
Clinical Safety and Quality Service II
HA Staff
K L CHAN
View All Abstracts
531
visits
Forgot your Password?
Disconnected from server
You are disconnected from the server. The changes you made may not be saved. Please check when connected.